01Product Description

Design and development in accordance with the requirements of standards such as "HJ/T 399-2007 Water Quality Chemical Oxygen Demand Rapid Digestion spectrophotometric method", "HJ 535-2009 Water Quality Determination of Ammonia Nitrogen Nessler's reagent spectrophotometric method", "GB 11893-1989 Water Quality Determination of Total Phosphorus Ammonium molybdate spectrophotometric method", and "GBT 5750-2006 Standard Test Method for Drinking Water". It has the characteristics of safe and simple operation, fast and accurate detection, and high degree of intelligence. It adopts microcomputer control technology and can directly read concentration. Suitable for the determination of total nitrogen, chemical oxygen demand (COD), ammonia nitrogen, total phosphorus, permanganate index, chromaticity, turbidity, as well as heavy metals such as copper, iron, zinc, manganese, nickel, and various water pollutants in drinking water, surface water, groundwater, domestic sewage, and industrial wastewater.



1. Wavelength range: 380-800nm

2. Display: 7-inch color LCD touch screen;

3. Filter: Standard with 4-wavelength filter;

4. Optical path system: Fiber optic spectroscopic detection system (ZL number:) ZL 2018 2 0182044.4);

5. Testing items: With nearly 50 preset testing items, it can directly measure COD, ammonia nitrogen, total phosphorus, total nitrogen, chromaticity, turbidity, and various inorganic pollutants; Multiple indicators including total chromium, nickel, copper, zinc, iron, lead and other heavy metals; At the same time, other items can be customized according to the detection requirements, and the setting program can be opened;

6. Storage: It can store 5 million pieces of detection data and can be freely accessed and viewed;

7. Pre stored curve: Pre stored factory standard curve, which can be revised and saved by oneself, or fitted by oneself,;

8. Digestion: comes standard with an independent digestion device;

9. Automatic calibration: The instrument has an automatic calibration function;

10. Printing method: standard built-in printer;

11. Data transmission: equipped with serial port transmission function;

12. Light source: LED light source is used to effectively ensure the stability of the light source;

13. Light source stability: ≤+0.001A/10min; Detection repeatability: ≤± 2%;

14. Detection position: DT3900 (tube colorimetric), DT3900 (dish colorimetric)


02Product Advantage

Product advantages and features

1Fast detection: The instrument adopts light source feedback technology, and the whole machine does not need to be preheated. It can be used immediately after startup and automatically compensates for the light source, extending the service life of the instrument;

2. Display: Adopting a 7-inch large screen color touch screen, the operation is comfortable, sensitive, the display effect is good, and the single page display content is rich;

3. Consumables: Customers can freely choose prefabricated consumables or powder consumables according to their needs;

4. Data upload: Detection data can be stored in large quantities or uploaded, with flexible and diverse methods for data storage and processing;

5. Curve chart: The instrument has powerful data processing capabilities and can display concentration curves, fitting curves, data charts, etc. without the need for an external computer. It can also be saved and printed;

6. Optical path system: The instrument adopts fiber optic splitting system technology to ensure the accuracy of detection precision;

7. Appearance: The casing is made of ABS material injection molded, which is not easy to age, beautiful and durable;

8. Cost effectiveness: The instrument has a rich comprehensive configuration, and the optical and circuit components are purchased from abroad, which has a high cost performance ratio compared to the same industry.




03FAQ
  • What are the reasons that affect the temperature uniformity of a constant temperature and humidity chamber?

    Cannot detect dead bacteria.

  • Principle of 4250 Freezing Point Penetrometer Determination Method
  • Can microbial detection bottles detect anaerobic bacteria?

    The detection range of the detection bottle includes anaerobic bacteria such as Clostridium sulfite reducing Clostridia, which produces gas

    Clostridium perfringens, including aerobic bacteria.

04Online Message
Product Name*
Name*
Phone*
Email*
Contury Or City
Message

Our company was founded in 2011.Our company specializes in the R&D, production, and manufacturing of molecular biology research instruments.

Copyright ©2025 Huatai Hehe (Beijing) Trading Co., LtdAll Rights Reserved.sitemap.xml

Product Name cannot be empty!
Name cannot be empty!
Please enter a valid phone number!
Please enter a valid E-mail!
Submitted Successfully
Submission Failed